INTO HANCHINE
INTO HANCHINE
HANCHINE Sharing | HANCHINE 3D Camera And EMC
DateTime:2021年01月14日
01 Introduction

In the industrial field, various devices often need to face severe electromagnetic interference. In order to cope with the increasingly complex electromagnetic environment, Hanzhen 3D cameras are designed from the source and pay great attention to the EMC performance of the products. The new products developed must be checked and checked one by one, and then tested and certified by professional certification agencies. Currently, all the 3D camera products launched have obtained the relevant electromagnetic compatibility certification of the industry.

02 What is EMC

Electromagnetic compatibility (EMC) terminology explanation: the ability of a device or system to work normally in its electromagnetic environment, and does not constitute unbearable electromagnetic disturbance to anything in the environment. (Refer to GB/T4765-1995)
From the above concepts, three elements of EMC can be sorted out: EMI, EMS, and electromagnetic environment.

2.1 EMI

EMI (Electro Magnetic Interference, electromagnetic interference), that is, the equipment or system in a certain environment, during normal operation, should not generate electromagnetic energy that exceeds the requirements of the corresponding standards.

2.2 EMS

EMS (Electro Magnetic Susceptibility, electromagnetic immunity) refers to a device or system in a certain environment. During normal operation, the device or system can withstand electromagnetic energy interference within the range specified by the corresponding standard.

2.3 Electromagnetic environment

Electromagnetic environment, that is, all kinds of electrical and electronic equipment that use electrical energy to work, together with the power supply of the equipment, the load, other electrical and electronic equipment around, the equipment operator or the person providing services for the equipment, and even other living substances, The specific working environment formed.

03 Main EMC test items

3.1 EMI test items

1.   Conducted disturbance of power line (CE)
  Signal and control line conduction disturbance (CE)
  Radiated disturbance (RE)
  Harmonic current measurement (Harmonic)
  Voltage fluctuation and flicker measurement (Fluctuation and Flicker)

3.2 EMS test items

11   Electrostatic discharge immunity (ESD)
  Electrical fast transient pulse group immunity (EFT/B)
  Surge (SURGE)
  Radiation immunity (RS)
  Conducted immunity (CS)
  Voltage drop and interruption (DIP)
  Power frequency magnetic field immunity (PMS)

04 Electromagnetic compatibility system standard

4.1 Principles of electromagnetic compatibility standards

4.2 Common electromagnetic compatibility standard number identification

05 On-site testing of some products of HANCHINE Camera

Conducted immunity test(CS)

 

Electrical fast transient pulse group immunity test(EFT/B

Electrostatic discharge immunity test(ESD)

Power frequency magnetic field immunity test(PMS)

Radiation immunity test(RS)

Làng yǒng cèshì
4 / 5000
翻译结果
Surge test 
(SURGE)

06 HANCHINE 3D Camera EMC Certification Report

07 Concluding remarks

For industrial products, it is not enough to obtain various EMC certification qualifications. Hanzhen is committed to continuously improving the electromagnetic compatibility performance of products to cope with the harsh industrial site electromagnetic environment under various complex conditions, ensuring the smooth and stable development of users' 3D vision projects Advance.